DOP 4 application ___________________________________________________________________________ DOP 4 V2.5.1.0 *A new search routine for the Modbus RTU interface has been added to the “Advanced search” dialog. *Connectivity to the COM ports has been improved so the false and annoying “Error: Open COM port” and the “No Device” messages have been almost eliminated. *The “Find Baud Rate” function is now enabled for the Modbus RTU interface. *Added shortcut “Input / Output” button to the extended “Mass Flow / Analog” dialog. *Minor errors have corrected. DOP 4 V2.5.0.0 *The “FV – Factory Calibration Value” and the “LN – Lin Point” commands have been added to the serial COM “Values Log View” dialog for devices supporting these commands. *The “Set Linearization Points” dialog is now available for both the LDU69 and the LDM15x devices in the Calibration dialog. *A “Terminal View” dialog has been added for the Profibus Interface. *Extended versions of the mass flow dialogs for the DAD141 device are now available for version 2.10 of the DAD141 device. *Minor errors using the Profibus interface corrected. DOP 4 V2.4.9.0 *CAN baud rate, CAN address and TPD01 Decimator have been added to the serial COM “Values Log View” dialog for newer devices supporting the CAN interface. DOP 4 V2.4.8.0 *Updated FIR values for the “Filter/Tare” dialog for devices having sample rate at 1200. *Updated IIR filter coefficients for the “Filter Analyzer” for devices having a sample rate at 1200. *Improvements and corrections have been done to the “Values Log View” dialog. The AZ and AG values are shown correctly for all device modes and a header with device information has been added. *The textual warning for having the DX value set to 0 has been improved with some more detailed explanation added. *Position of “Linearization” button in the “Calibration Dialog” for the LDU69 device has been corrected. *The “Communication” dialog has been corrected for the LDB152 device. (No CANopen interface). *Error when having the character ‘-‘ alone in AL and AH field in “Analog” Dialog corrected. DOP 4 V2.4.7.0 *CSV files can now be saved with a specified time interval between the different data samples. DOP 4 V2.4.6.0 *New “Average Calculator” dialogs have been added to the “Average Measurement” and the “Filter Analyzer” dialogs. *Updates and corrections to match the new hardware versions of the DAD series having version 2.x introduced. DOP 4 V2.4.3.0 *Date / Time for start of record can now be added to the first line of CSV files. *Scope data can now ongoing be written to temporary CSV files while recording Long Time data. *Scope data can now be reloaded to the scope display channel by channel from CSV scope data files. *Calibration dialog has changed so the user can select between calibration by weight on load cell or by entering calibration data manually. *Improved correction of illegal IP address texts. (Leading zeros are removed) *AZ and AG are read only in the Calibration dialog when using the LDU181 and the QLC162 devices. DOP 4 V2.4.1.0 *Version header corrected. DOP 4 V2.4.0.0 *Support for LDU178 added. *Negative trigger values are now accepted. *The ZN and ZM commands have been added to the Calibration Dialog. *Auto save of CSV files from the Average Measurement dialog introduced. *SD command range error for LDM64 corrected. *Minor improvements and corrections have been done. DOP 4 V2.3.1.0 *A number of major and minor improvements and error corrections have been done. *Better handling of half duplex devices. *Better handling of multi devices on one COM port with ASCII / ModbusRTU interface. DOP 4 V2.3.0.0 *Support for new devices DAD143 and LDU181 introduced. *New “Counting Items” dialog have been introduced. The new dialog is accessible from the “Dialog Select” menu which pops up when the mouse cursor is moved to an active weight display in the main window. First time opening the dialog, select the “Setup” button for calibrating items. Nothing is stored or changed in the devices. Only in the DOP 4 application. You can have the “Counting Items” and the “Display Panel” dialogs opened at the same time. *Function for polling data introduced. No record possible, but you can monitor half duplex devices and multi devices using the same COM port. Just uncheck the new “Stream” checkbox which has replaced the old “Pop Up” checkbox which didn’t serve a real purpose anymore. *Polling data is also introduced for the “Channels Sum” dialog. Just uncheck the new “Stream” checkbox. No record possible in this mode. *Warning for baud rate too low inserted in a number of streaming dialogs informing the user if the baud rate or the update rate devisor should be raised. *Improved setting of the AG value for MODbus, CANOpen and PROFIbus using a new CV command has been introduced for certain devices updated with the CV command. *A number of minor improvements and error corrections have been done. DOP 4 V2.2.0.0 *Support for drop filler functionality is added for the LDM64 device. *The resolution and accuracy of the sampling in the “Channels Sum” dialog has been increased by changing the sample method from polling data to streaming data. *Auto wait functionality has been added to the “Channels Sum” dialog. *A “Filter Analyzer” button is added to the “Average Measurement” dialog for direct access to the filter analyzer during an average measurement session. *A “Dosed Weight Log” is introduced in the filler measurement dialogs. *Min and Max pointers modified. Labels removed. *“Average Measurement” dialog improved for use of retrigger function. *Set Preset Tare command added to the “Filter / Tare” dialog. *An error influencing the accuracy of recording streamed data from the main window over a daytime is corrected. *An error causing recording to fail, when using the CANopen interface for continuous recording over an hour is corrected. *An error causing loss of time stamp accuracy when recording using MODbus and PROFIbus interface on a Windows 10 PC is corrected. *Error in Average measurement using LDU68 device corrected. DOP 4 V2.1.0.0 *A “Tare Selected Channels” function has been added to the “Channels Sum” dialog. The function does a tarring of up to 4 devices at once. *A New “Trigger” graph is added to the “Average Measurement” dialog, showing all recorded triggers. *The edges of the recorded Average values in the “Average Measurement” dialog have been slightly adjusted so they appear with the correct steep. *Auto wait functionality has been added to the “Average Measurement” dialog. *Reload of scope data has been added to the “Average Measurement” dialog. *Calibration of “Zero” and “Span” can now be canceled by button before it’s executed. *The “Terminal View” dialog is now accessible from the “Commands View” dialog. *For the LDU179, LDB151 and LDB152, support for changing between “Modbus RTU” and “ASCII” mode has been added to the “Communication” dialog. *A number of wrong parameter range values have been corrected. *Index Input added to the CAN open “Terminal View” dialog *The text of the “Measure” buttons in main window, have been changed to “Average”, “Mass Flow” or “Filling”. *A number of new functionalities are added to the “Mass Flow” measure and “Mass Flow” parameters dialogs. *A number of minor errors have been corrected. DOP 4 V2.0.2.0 *Support for LDM151 and LDM152 filler functionality. *Minor errors corrected. DOP 4 V2.0.0.0 *New Setpoints / Outputs Measurement dialog introduced. *Average graph added to the Average Measurement dialog. DOP 4 V1.9.8.0 *New Drop Filling dialogs for the DAD141.1 are introduced. DOP 4 V1.9.7.0 *Modbus RTU supported for LDB151, LDB152 and LDU179 devices. DOP 4 V1.9.6.0 *Channels Sums dialog introduced *Motion / No motion dialog introduced DOP 4 V1.9.5.0 *Support for LDB152 device DOP 4 V1.9.4.0 *Support for special LDU78 DOP 4 V1.9.3.0 *Serious error in reading Modbus command values has been corrected DOP 4 V1.9.2.0 *Support for DAD141 mass flow and filling functionality now fully updated. *Adjustment has been made to some dialogs which weren’t shown correctly on screens set to 125 %. DOP 4 V1.9.1.0 *Access to a new “Send Average Log” dialog has been introduced in the “Average Measurement” dialog. *Access to a new “Analog” dialog has be introduced for the DAD141 device in the “Commands View”. DOP 4 V1.9.0.0 *Mass flow measurement dialog has been introduced for the DAD141. *General support for mass flow (loss in weight) devices. *Support for LDM64 in filler mode. *CANopen setup for LDM64 has been introduced. *Major and minor errors corrected. (Error when assigning negative numbers to AZ and AG command parameters) DOP 4 V1.8.1.0 *Modbus Terminal dialog introduced. *CSV auto save function introduced. *LDB 151 Input / Output dialog now supports 3 input and 4 output indicators. *Major and minor errors corrected. (Using Popup dialog having multi LDM connected) DOP 4 V1.8.0.0 *Filter Analyzer dialog introduced. DOP 4 V1.7.1.0 *Errors using ProfiBus and Modbus corrected. DOP 4 V1.7.0.0 *Sequencer dialog introduced. DOP 4 V1.6.3.0 *Checkweigher dialogs changed. *Display units in Display Panel dialog. *Minor errors corrected. DOP 4 V1.6.2.0 *Modbus RTU. *Massflow DAD141. *Address Settings WCN122 updated *Lin points for LDU 69 DOP 4 V1.6.1.0 *Tool Tips updated. *Error in Calibration Dialog saving for LDM. DOP 4 V1.6.0.0 *Auto retrigger introduced in main screen. *Advanced device search dialog introduced. *Display panel for showing big weight display introduced. *Log view dialog introduced for saving and printing command parameters values. *Dialog for setting up Serial COM parameters introduced. DOP 4 V1.5.1.0 *New dialog “Setup Functional Units” for the WCN122 device is introduced. *Network settings dialog introduced for the WCN122 and the DAD141. *Multiple baud rates for the same COM port now accepted in the Selected Devices view. DOP 4 V1.5.0.0 *Streamed multi channel recording for all 4 device channels at the same time by using the “Record All” button has been introduced. *The Calibration dialog has been expanded so all calibration command parameters are now included in the dialog. *The “Filter / Tare” dialog has been expanded with zeroing commands. *Soft buttons have been introduced for the serial “Terminal View” dialog DOP 4 V1.4.1.0 *Selectable tool tip support has been introduced for the German language. *Different application settings can be done from the General Configuration dialog. *Hold Time parameter field added to the Input / Output dialogs *Under and over range indications in main weight displays. *Reload and connection of previous devices at DOP 4 startup. *A number of minor errors corrected. DOP 4 V1.4.0.0 *Selectable tool tip support has been introduced for the English language. *The command library has in general been updated and corrected for a number of different devices. *Different headers have been updated with device information. *A number of minor errors corrected. DOP 4 V1.3.1.0 *Modbus interface for DAD 141 introduced. *DOP 4 user manuals are updated from revision 1.1 to 1.2. DOP 4 V1.3.0.0 *“Motion / Stable” indicator introduced in the “Filter / Tare” and “Calibration” dialogs. *“Input / Output” dialog with Setpoints introduced in “Commands View” and as pop-up. *New “Import / Export” dialog replacing the old “Get / Put” image dialog. *“Checkweigher / Filling” dialog introduced in “Commands View”. DOP 4 V1.2.1.0 *S0, H0, A0 and P0 command support for DAD141 introduced. *Track bar introduced for easy scrolling through large amount of scope data. DOP 4 V1.2.0.0 *Support for Profibus interface introduced. *Support for LDM version 8816 introduced. *DOP 4 V1.1.1.0 *Support for DAD 141 introduced. *Serial LAN interface introduced. DOP 4 V1.0.0.0 *Initial official release of the DOP 4 application. Previous DOP applications _______________________________________________________________________________________ DOP.v.2.0.9 *The WCN 121.1 is now recognized as a 7813... firmware bug fixed so GetPacket (GP) data transmit the correct check-weigher states! DOP.v.2.0.8 21/10-08 16:52 *Removed baudrate selection and autodetect of baudrate. Now fixed to 230400baud Removed read/write of checkweigher values when pressing GetAverage button DOP.v.2.0.6 12/12-07 16:24 *problem with showing DAS 77xx tabsheet fixed DOP.v.2.0.5 04/12-07 12:49 *Exampels and notes added in terminal window in the command tabsheet! DOP.v.2.0.4 28/11-07 15:49 *Update to work with DAP91.1 *Problem with finding LDM module after calibration - Fixed! *NEW* Now possible to send set of commands to multiple device *NEW* Now possible to load image to multiple device DOP.v.2.0.3 31/10-07 *Bug when using COM3 and pressing find device fixed! DOP.v.2.0.2 26/6-07 *minor changes regarding USB2CAN... some CAN problems not solved yet! DOP.v.2.0.1 6/6-07 *Bug in Updaterate selection UR7 corrected! DOP.v.2.0.0.43 11/05-2007 16:45 *Some improvement of the get average functions for LDU's! DOP.v.2.0.0.40 11/05-2007 11:56 *Problem with changing filters on LDU 68.1 and 69.1 fixed. DOP.v.2.0.0.39 2/5-2007 20:32 *Improved interface to PC6D, Can do basics things, but not all commands are available yet DOP.v.2.0.0.38 30/4-2007 16:08 *Problem in re-draw function, when re-drawing gross data - fixed *Calibration procedure does not change filtersettings to 1Hz under calibration, but use selected filter under calibration DOP.v.2.0.0.37 23/4-2007 22:40 *problem showing average values in version 2.0.0.35 and 2.0.0.36 fixed! *Problem with re-draw in version 2.0.0.35 and 2.0.0.36 fixed! DOP.v.2.0.0.35 - 2.0.0.36 (Hannover messe) 18/4-2007 16:19 *PCAN_USB.sys driver (from 15/6 2005, 17:39:06 - 252kb) added to installation Solve same problem as starting DOP 2.0.0.30 after termination... newer driver seems to makes same problem! *Checkweigher setup is frozen if page is left with "get average" started *Missing average after showing checkweigher graph DOP.v.2.0.0.34 17/4-2007 13:58 Bug fixed: *average values is not displayed when "Nettovalues" are selected only when "Grossvalues" are selected *Problem displaying negative values in graphs DOP.v.2.0.0.33 13/4-2007 15:27 *Some devices has problems downloading a image-file at 115200baud. The Download has now been slow down. DOP.v.2.0.0.32 13/3-2007 13:35 *Gros/Netto display improved *Search only selected comport function added DOP.v.2.0.0.31 6/3-07 13:47 *Filtersettings now stable *FindDevice... added CL command DOP.v.2.0.0.30 5/3-2007 17:22 *New PCAN_USB.dll driver... If DOP was terminated by Ctrl+Alt+Del The computer had to be restarted before DOP will work again! Problem fixed! *Bug fixed...Problem when calibrating device with address like LDM modules. DOP.v.2.0.0.28 *Bug with ShowCMD fixed DOP.v.2.0.0.27 *More checkweigher commands added to the command tabsheet *Bug with LDM8813 checkweigher and status indo fixed DoP.v.2.0.0.26 *Some new improvementson the command tabsheet DOP.v.2.0.0.25 *Problem with no support for LDM88xx and the TxDelay command fixed DOP.v.2.0.0.24 *LongTermSample function bug fixed... Max 500.000 samples! 500.000 samples is the DOP Sample-limit (Eks: 600 samples/sec ~ 14 hours) The LongTermSample option makes it possible to use the DOP to record data over many days! DOP.v.2.0.0.23 *Bug with 'SA' SendAverage fixed... and SendAverage bug in firmware 78.183.v.2.32, and v2.33 fixed and updated to 78.183.v.2.34 *CAN adaptor errormessage on end application fixed DOP.v.2.0.0.22 *Support for USB to CAN adapter together with PC6D DOP.v.2.0.0.21 *Calipration window optimized for 120dpi font size *Commands update(S0-S3, H0-H3, A0-A3) DOP.v.2.0.0.20 *All H&B commands are now available as buttons under the >Command< tabsheet. You can also type in simple "to-do-strings" to make setup or test easier. *Support up to 8 comports *Support 96 or 120 dpi text size